ON BOARD DIAGNOSTIC (OBD) SYSTEM
Trouble Diagnosis without CONSULT-III
DIAGNOSTIC PROCEDURE 6
Inspect SRS Malfunction Using "AIR BAG" Warning Lamp--Diagnosis Mode
NOTE:
SRS will not enter Diagnosis mode if no malfunction is detected in User mode.
- Turn ignition switch ON.
- After "AIR BAG" warning lamp lights for 7 seconds, turn ignition switch OFF within 1 second.
- Wait more than 3 seconds.
- Repeat steps 1 to 3 two more times (3 times total).
- Turn ignition switch ON. SRS is now in Diagnosis mode. Refer to See: Scan Tool Testing and Procedures\Diagnosis Sensor Unit\Trouble Diagnosis Without CONSULT-III.
|