Your Vehicle: 2001 Ford Escort ZX2 L4-2.0L DOHC VIN 3
 
Vehicle » Heating and Air Conditioning » Coupler HVAC » Service and Repair » Peanut Fitting Connect and Disconnect Procedure  
 
 
  Peanut Fitting Connect and Disconnect Procedure  
 

DISCONNECT

  

  1. Remove the nut from the peanut fitting.

CAUTION: Support the female fitting with a wrench to prevent the tubes from twisting.

  

  1. Pull the peanut fitting apart.

  

  1. Remove the O-ring seal with a non-metallic tool.

CAUTION: Do not use metal tools to remove the O-ring seal. They can cause axial scratches across the O-ring seal groove resulting in refrigerant leaks.

CONNECT

  1. Clean all dirt or foreign material from the fittings.

  

  1. Install the O-ring seal.
    • Lubricate the O-ring seal with PAG Refrigerant Compressor Oil (R-134a Systems) F7AZ-19589-DA (Motorcraft YN-12-C) or equivalent meeting Ford specification WSH-M1C231-B.

CAUTION: Use only new purple O-ring seals. The use of any O-ring seals other than specified may result in intermittent leakage during vehicle operation.

  1. Lubricate the inside of the fittings with PAG Refrigerant Compressor Oil (R-134a Systems) F7AZ-19589-DA (Motorcraft YN-12-C) or equivalent meeting Ford specification WSH-M1C231-B.

  

  1. Assemble the male and female fittings together.

NOTE: When correctly assembled, the male and female fittings should be flush.