Your Vehicle: 2001 Ford Escort ZX2 L4-2.0L DOHC VIN 3
 
Vehicle » Heating and Air Conditioning » Service and Repair » Identifying Refrigerants  
 
 
  Identifying Refrigerants  
 

A/C Refrigerant Analyzer
  

SPECIAL TOOL(S)

  1. Follow the instructions included with the Deluxe Refrigerant Diagnostic Tool to obtain the sample for testing.

NOTE: An A/C refrigerant analyzer must be used to identify gas samples taken directly from the refrigeration system or storage containers prior to recovering or charging the refrigerant system.

  1. The diagnostic tool will display one of the following:
    • If the purity level of R-134a or R-12 is 98% or greater by weight, the green "PASS" Light Emitting Diode (LED) will light. The weight concentrations of R-134a, R-12, R-22, hydrocarbons, and air will be displayed on the digital display.
    • If refrigerants R-134a or R-12 do not meet the 98% purity levels, the red "FAIL" LED will light and a horn will sound alerting the user of potential hazards. The weight concentrations of R-134a, R-12, R-22, and hydrocarbons will be displayed on the digital display.
    • If hydrocarbon concentrations are 2% or greater by weight, the red "FAIL" LED will light, "Hydrocarbon High" will be displayed on the digital display, and a horn will sound alerting the user of potential hazards. The weight concentrations of R-134a, R-12, R-22, and hydrocarbons will also be displayed on the digital display.
  1. The percentage of air contained in the sample will be displayed if the R-134a or R-12 content is 98% or greater. The diagnostic tool eliminates the effect of air when determining the refrigerant sample content because air is not considered a contaminant, although air can affect A/C system performance. When the diagnostic tool has determined that a refrigerant source is pure (R-134a or R-12 is 98% or greater by weight) and air concentration levels are 2% or greater by weight, the diagnostic tool will prompt the user if an air purge is desired.
  2. If contaminated refrigerant is detected, repeat the refrigerant identification test to verify that the refrigerant is indeed contaminated.
  3. Recover any contaminated refrigerant using suitable recovery-only equipment designed for capturing and storing contaminated refrigerant.

CAUTION: If contaminated refrigerant is detected, DO NOT recover the refrigerant into R-134a or R-12 recovery/recycling equipment.