CAUTION:
- When installing a new A/C compressor due to an internal failure of the old unit, you must carry out the following procedures to remove contamination from the air conditioning system:
- If A/C flushing equipment is available, carry out flushing of the air conditioning system.
- If A/C flushing equipment is not available, carry out filtering of the air conditioning system.
- Install a new evaporator core orifice.
- Install a new suction accumulator.
- Plug all ports to prevent contamination from dirt or moisture.
|